SchwörerHaus WGT BIC VentCube Fresh Home Assistant Integration via modbus
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
# Helpful information: | |
# https://github.com/Excodibur/ioBroker.schwoerer-ventcube/blob/master/src/lib/schwoerer/parameters.ts | |
# https://github.com/fgoettel/wgt/blob/main/wgt/lueftungsanlage.py | |
# https://knx-user-forum.de/forum/öffentlicher-bereich/knx-eib-forum/diy-do-it-yourself/1822296-modbus-schwörer-heizung?p=1906252#post1906252 | |
################## | |
# MODBUS SENSORS # | |
################## | |
modbus: | |
- name: BIC_VentCube | |
delay: 2 | |
timeout: 3 | |
type: tcp | |
host: !secret wgt_ip | |
port: 502 | |
sensors: | |
- name: VentCube Betriebsart | |
slave: 1 | |
unique_id: ventcube_betriebsart | |
address: 100 | |
# Translated with template sensor | |
# Translated with input_select Automation | |
- name: VentCube Manuelle Luftstufe | |
slave: 1 | |
unique_id: ventcube_manuelle_luftstufe | |
address: 101 | |
# Translated with input_select Automation | |
- name: VentCube Aktuelle Luftstufe | |
slave: 1 | |
unique_id: ventcube_aktuelle_luftstufe | |
address: 102 | |
- name: VentCube Status Stoßlüftung | |
slave: 1 | |
unique_id: ventcube_status_stosslueftung | |
address: 111 | |
# Translated with template sensor | |
- name: VentCube Restlaufzeit Stoßlüftung | |
slave: 1 | |
unique_id: ventcube_restlaufzeit_stosslueftung | |
address: 112 | |
unit_of_measurement: min | |
device_class: duration | |
min_value: 0 | |
max_value: 60 | |
- name: VentCube Status Wärmepumpe | |
slave: 1 | |
unique_id: ventcube_status_waermepumpe | |
address: 114 | |
# Translated with template sensor | |
- name: VentCube Status Nachheizregister | |
slave: 1 | |
unique_id: ventcube_status_nachheizregister | |
address: 116 | |
# Translated with template sensor | |
- name: VentCube Status Gebläse Zuluft | |
slave: 1 | |
unique_id: ventcube_status_geblaese_zuluft | |
address: 117 | |
# Translated with template sensor | |
- name: VentCube Status Gebläse Abluft | |
slave: 1 | |
unique_id: ventcube_status_geblaese_abluft | |
address: 118 | |
# Translated with template sensor | |
- name: VentCube Bypass Zustand | |
slave: 1 | |
unique_id: ventcube_bypass_zustand | |
address: 123 | |
# Translated with template sensor | |
- name: VentCube Zustand Außenklappe | |
slave: 1 | |
unique_id: ventcube_zustand_aussenklappe | |
address: 131 | |
# Translated with template sensor | |
- name: VentCube Status Vorheizregister | |
slave: 1 | |
unique_id: ventcube_status_vorheizregister | |
address: 133 | |
# Translated with template sensor | |
- name: VentCube aktuelle Luftleistung Zuluft | |
slave: 1 | |
unique_id: ventcube_aktuelle_luftleistung_zuluft | |
address: 142 | |
state_class: measurement | |
unit_of_measurement: "%" | |
min_value: 0 | |
max_value: 100 | |
scale: 1 | |
precision: 0 | |
- name: VentCube aktuelle Luftleistung Abluft | |
unique_id: ventcube_aktuelle_luftleistung_abluft | |
slave: 1 | |
address: 143 | |
state_class: measurement | |
unit_of_measurement: "%" | |
min_value: 0 | |
max_value: 100 | |
scale: 1 | |
precision: 0 | |
- name: VentCube aktuelle Drehzahl Zuluft | |
unique_id: ventcube_aktuelle_drehzahl_zuluft | |
slave: 1 | |
address: 144 | |
state_class: measurement | |
unit_of_measurement: "rpm" | |
min_value: 0 | |
max_value: 10000 | |
precision: 0 | |
- name: VentCube aktuelle Drehzahl Abluft | |
unique_id: ventcube_aktuelle_drehzahl_abluft | |
slave: 1 | |
address: 145 | |
state_class: measurement | |
unit_of_measurement: "rpm" | |
min_value: 0 | |
max_value: 10000 | |
precision: 0 | |
- name: VentCube T2 Temperatur nach Vorheizregister | |
slave: 1 | |
unique_id: ventcube_t2_temperatur_nach_vorheizregister | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 201 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube T3 Temperatur vor Nacherwärmung | |
slave: 1 | |
unique_id: ventcube_t3_temperatur_vor_nacherwaermung | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 202 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube T4 Temperatur nach Nacherwärmung | |
slave: 1 | |
unique_id: ventcube_t4_temperatur_nach_nacherwaermung | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 203 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube T5 Temperatur Abluft | |
slave: 1 | |
unique_id: ventcube_t5_temperatur_abluft | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 204 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube T6 Temperatur im Wärmetauscher | |
slave: 1 | |
unique_id: ventcube_t6_temperatur_im_waermetauscher | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 205 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube T10 Temperatur Außen | |
slave: 1 | |
unique_id: ventcube_t10_temperatur_aussen | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 209 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube Heiz- Kühlfunktion | |
slave: 1 | |
unique_id: ventcube_heiz_kuehlfunktion | |
address: 230 | |
# Translated with template sensor | |
# Translated with input_select Automation | |
- name: VentCube Wärmepumpe Heizen | |
slave: 1 | |
unique_id: ventcube_wp_heizen | |
address: 231 | |
- name: VentCube Wärmepumpe Kühlen | |
slave: 1 | |
unique_id: ventcube_wp_kuehlen | |
address: 232 | |
- name: VentCube Druckwächter aktiv | |
slave: 1 | |
unique_id: ventcube_druckwachter_aktiv | |
address: 242 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube EVU Sperre aktiv | |
slave: 1 | |
unique_id: ventcube_evu_sperre_aktiv | |
address: 243 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube Wartungstür offen | |
slave: 1 | |
unique_id: ventcube_wartungstur_offen | |
address: 244 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube Gerätefilter verschmutzt | |
slave: 1 | |
unique_id: ventcube_geratefilter_verschmutzt | |
address: 245 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube Vorgelagerter Filter verschmutzt | |
slave: 1 | |
unique_id: ventcube_vorgelagerter_filter_verschmutzt | |
address: 246 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube Zuluft zu kalt | |
slave: 1 | |
unique_id: ventcube_zuluft_zu_kalt | |
address: 254 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube Restlaufzeit Gerätefilter | |
slave: 1 | |
unique_id: ventcube_restlaufzeit_geratefilter | |
address: 265 | |
unit_of_measurement: d | |
min_value: 0 | |
max_value: 255 | |
device_class: duration | |
- name: VentCube Temperatur Wohnzimmer IST | |
slave: 1 | |
unique_id: ventcube_temperatur_wohnzimmer_ist | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 360 | |
scale: 0.1 | |
precision: 1 | |
min_value: 0 | |
max_value: 100 | |
switches: | |
- name: VentCube Freigabe WP auf Heizen | |
slave: 1 | |
address: 231 | |
command_on: 0x1 # Freigabe | |
command_off: 0x0 # Gesperrt | |
write_type: holdings | |
verify: | |
input_type: holding | |
state_on: 0x1 | |
state_off: 0x0 | |
delay: 5 | |
unique_id: ventcube_set_waermepumpe_heizen | |
- name: VentCube Freigabe WP auf Kühlen | |
slave: 1 | |
address: 232 | |
command_on: 0x1 # Freigabe | |
command_off: 0x0 # Gesperrt | |
write_type: holdings | |
verify: | |
input_type: holding | |
state_on: 0x1 | |
state_off: 0x0 | |
delay: 5 | |
unique_id: ventcube_set_waermepumpe_kuehlen | |
climates: | |
- name: "VentCube Soll-Temperatur" | |
unique_id: ventcube_soll_temperatur | |
slave: 1 | |
address: 400 | |
max_temp: 30 | |
min_temp: 10 | |
offset: 0 | |
precision: 0 | |
scale: 0.1 | |
target_temp_register: 400 | |
target_temp_write_registers: true | |
temp_step: 1 | |
temperature_unit: °C | |
- name: "VentCube Basis-Temperatur" | |
unique_id: ventcube_basis_temperatur | |
slave: 1 | |
address: 420 | |
max_temp: 30 | |
min_temp: 18 | |
offset: 0 | |
precision: 0 | |
scale: 0.1 | |
target_temp_register: 420 | |
target_temp_write_registers: true | |
temp_step: 1 | |
temperature_unit: °C | |
##################################################### | |
# Select Options which require separate Automations # | |
##################################################### | |
input_select: | |
ventcube_manuelle_luftstufe: | |
name: VentCube Manuelle Luftstufe | |
options: | |
- "0 - Aus" | |
- "1 - Stufe 1" | |
- "2 - Stufe 2" | |
- "3 - Stufe 3" | |
- "4 - Stufe 4" | |
- "5 - Automatik" | |
- "6 - Linearbetrieb" | |
icon: mdi:fan | |
ventcube_betriebsart: | |
name: VentCube Betriebsart | |
options: | |
- "0 - Aus" | |
- "1 - Handbetrieb" | |
- "2 - Winterbetrieb" | |
- "3 - Sommerbetrieb" | |
- "4 - Sommer Abluft" | |
icon: mdi:fan | |
ventcube_heiz_kuehlfunktion: | |
name: VentCube Heiz- Kühlfunktion | |
options: | |
- "0 - Aus" | |
- "1 - Heizen" | |
- "2 - Kühlen" | |
- "3 - Auto T-Außen" | |
- "4 - Auto Digitaler Eingang" | |
icon: mdi:fan | |
#################### | |
# TEMPLATE SENSORS # | |
#################### | |
sensor: | |
- platform: template | |
sensors: | |
ventcube_betriebsart_text: | |
unique_id: ventcube_betriebsart_text | |
friendly_name: "VentCube Betriebsart" | |
value_template: > | |
{% set mapper = { | |
'0': 'Aus', | |
'1': 'Handbetrieb', | |
'2': 'Winterbetrieb', | |
'3': 'Sommerbetrieb', | |
'4': 'Sommer Abluft'} %} | |
{% set state = states.sensor.ventcube_betriebsart.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_bypass_zustand_text: | |
unique_id: ventcube_bypass_zustand_text | |
friendly_name: "VentCube Zustand Bypass" | |
value_template: > | |
{% set mapper = { | |
'0': 'Geschlossen', | |
'1': 'Offen (Kühlen)', | |
'2': 'Offen (Heizen)'} %} | |
{% set state = states.sensor.ventcube_bypass_zustand.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_zustand_aussenklappe_text: | |
unique_id: ventcube_zustand_aussenklappe_text | |
friendly_name: "VentCube Zustand Außenklappe" | |
value_template: > | |
{% set mapper = { | |
'0': 'Geschlossen', | |
'1': 'Offen'} %} | |
{% set state = states.sensor.ventcube_zustand_aussenklappe.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_waermepumpe_text: | |
unique_id: ventcube_status_waermepumpe_text | |
friendly_name: "VentCube Status Wärmepumpe" | |
value_template: > | |
{% set mapper = { | |
'0': 'Aus', | |
'5': 'WP Heizen', | |
'49': 'WP Kühlen'} %} | |
{% set state = states.sensor.ventcube_status_waermepumpe.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_heiz_kuehlfunktion_text: | |
unique_id: ventcube_heiz_kuehlfunktion_text | |
friendly_name: "VentCube Status Heiz- Kühlfunktion" | |
value_template: > | |
{% set mapper = { | |
'0': 'Aus', | |
'1': 'Heizen', | |
'2': 'Kühlen', | |
'3': 'Auto T-Außen', | |
'4': 'Auto Digitaler Eingang'} %} | |
{% set state = states.sensor.ventcube_heiz_kuehlfunktion.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_nachheizregister_text: | |
unique_id: ventcube_status_nachheizregister_text | |
friendly_name: "VentCube Status Nachheizregister" | |
value_template: > | |
{% set mapper = { | |
'0': 'Inaktiv', | |
'1': 'Aktiv'} %} | |
{% set state = states.sensor.ventcube_status_nachheizregister.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_vorheizregister_text: | |
unique_id: ventcube_status_vorheizregister_text | |
friendly_name: "VentCube Status Vorheizregister" | |
value_template: > | |
{% set mapper = { | |
'0': 'Aus', | |
'1': 'VHR1 Aktiv', | |
'2': 'VHR2 Aktiv', | |
'3': 'VHR1+2 Aktiv'} %} | |
{% set state = states.sensor.ventcube_status_vorheizregister.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_stosslueftung_text: | |
unique_id: ventcube_status_stosslueftung_text | |
friendly_name: "VentCube Status Stoßlüftung" | |
value_template: > | |
{% set mapper = { | |
'0': 'Inaktiv', | |
'1': 'Aktiv'} %} | |
{% set state = states.sensor.ventcube_status_stosslueftung.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_geblaese_zuluft_text: | |
unique_id: ventcube_status_geblaese_zuluft_text | |
friendly_name: "VentCube Status Gebläse Zuluft" | |
value_template: > | |
{% set mapper = { | |
'0': 'Deaktiviert', | |
'1': 'Anlaufphase', | |
'2': 'Aktiv', | |
'5': 'Standby', | |
'6': 'Fehler'} %} | |
{% set state = states.sensor.ventcube_status_geblaese_zuluft.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_geblaese_abluft_text: | |
unique_id: ventcube_status_geblaese_abluft_text | |
friendly_name: "VentCube Status Gebläse Abluft" | |
value_template: > | |
{% set mapper = { | |
'0': 'Deaktiviert', | |
'1': 'Anlaufphase', | |
'2': 'Aktiv', | |
'5': 'Standby', | |
'6': 'Fehler'} %} | |
{% set state = states.sensor.ventcube_status_geblaese_abluft.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
template: | |
- binary_sensor: | |
- name: "VentCube Meldung Druckwächter Aktiv" | |
unique_id: ventcube_meldung_druckwachter_aktiv | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'off', | |
'1': 'on'} %} | |
{% set state = states.sensor.ventcube_druckwachter_aktiv.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
- name: "VentCube Meldung EVU Sperre aktiv" | |
unique_id: ventcube_meldung_evu_sperre_aktiv | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'off', | |
'1': 'on'} %} | |
{% set state = states.sensor.ventcube_evu_sperre_aktiv.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
- name: "VentCube Meldung Wartungstür offen" | |
unique_id: ventcube_meldung_wartungstur_offen | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'off', | |
'1': 'on'} %} | |
{% set state = states.sensor.ventcube_wartungstur_offen.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
- name: "VentCube Meldung Gerätefilter verschmutzt" | |
unique_id: ventcube_meldung_geratefilter_verschmutzt | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'off', | |
'1': 'on'} %} | |
{% set state = states.sensor.ventcube_geratefilter_verschmutzt.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
- name: "VentCube Meldung Vorgelagerter Filter verschmutzt" | |
unique_id: ventcube_meldung_vorgelagerter_filter_verschmutzt | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'on', | |
'1': 'off'} %} | |
{% set state = states.sensor.ventcube_vorgelagerter_filter_verschmutzt.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
- name: "VentCube Meldung Zuluft Zu Kalt" | |
unique_id: ventcube_meldung_zuluft_zu_kalt | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'off', | |
'1': 'on'} %} | |
{% set state = states.sensor.ventcube_zuluft_zu_kalt.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Hello ;)
für mich ist das mit Modus und Co noch relatives Neuland. Habe jetzt aber im Grunde die Schritte wie beschrieben ausgeführt. Bekomme jedoch bei "Entwicklerwerkzeuge" -> "YAML" bei Konfiguration prüfen folgende Fehlermeldung.
Konfigurationswarnungen
Invalid config for 'modbus' at configuration.yaml, line 12: 'input_select' is an invalid option for 'modbus', check: modbus->0->input_select
Invalid config for 'modbus' at configuration.yaml, line 12: 'modbus' is an invalid option for 'modbus', check: modbus->0->modbus
Invalid config for 'modbus' at configuration.yaml, line 12: 'sensor' is an invalid option for 'modbus', check: modbus->0->sensor
Invalid config for 'modbus' at configuration.yaml, line 12: 'template' is an invalid option for 'modbus', check: modbus->0->template
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'baudrate' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'bytesize' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'method' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'parity' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'port' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'stopbits' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'type' not provided
Hat jemand ne Idee und kann mir hier weiterhelfen? Danke vorab
Grüße
Dani