Simple script to control pwm fans using a defined curve; requires a companion script to actually send the correct command to the fan controller.
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
#!/bin/bash | |
INTERVAL="10s" | |
INPUT_DRIVER="coretemp" | |
#TEMP_PATH="/sys/class/hwmon/hwmon3/temp1_input" | |
FAN_CMD="/usr/bin/fan.sh" | |
# Find correct input temperature path | |
for hwmon in `ls /sys/class/hwmon/`; do | |
driver=$(</sys/class/hwmon/$hwmon/name) | |
if [ "$driver" == "$INPUT_DRIVER" ]; then | |
break | |
fi | |
done | |
TEMP_PATH="/sys/class/hwmon/$hwmon/temp1_input" | |
CURVE=lin_curve | |
lin_curve() { | |
m=11 | |
q=-640 | |
echo "obase=16; r = $m * $1 + $q; if ( r<48 ) 0 else r" | bc | |
} | |
while true; do | |
temp="$(( $(cat $TEMP_PATH) / 1000 ))" | |
${FAN_CMD} "$($CURVE $temp)" | |
sleep "${INTERVAL}" | |
done |