Reading PZEM-004t power sensor (new version v3.0) through Modbus-RTU protocol over TTL UART
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
# Reading PZEM-004t power sensor (new version v3.0) through Modbus-RTU protocol over TTL UART | |
# Run as: | |
# python3 pzem_004t.py | |
# To install dependencies: | |
# pip install modbus-tk | |
# pip install pyserial | |
import serial | |
import modbus_tk.defines as cst | |
from modbus_tk import modbus_rtu | |
# Connect to the sensor | |
sensor = serial.Serial( | |
port='/dev/PZEM_sensor', | |
baudrate=9600, | |
bytesize=8, | |
parity='N', | |
stopbits=1, | |
xonxoff=0 | |
) | |
master = modbus_rtu.RtuMaster(sensor) | |
master.set_timeout(2.0) | |
master.set_verbose(True) | |
data = master.execute(1, cst.READ_INPUT_REGISTERS, 0, 10) | |
voltage = data[0] / 10.0 # [V] | |
current = (data[1] + (data[2] << 16)) / 1000.0 # [A] | |
power = (data[3] + (data[4] << 16)) / 10.0 # [W] | |
energy = data[5] + (data[6] << 16) # [Wh] | |
frequency = data[7] / 10.0 # [Hz] | |
powerFactor = data[8] / 100.0 | |
alarm = data[9] # 0 = no alarm | |
print('Voltage [V]: ', voltage) | |
print('Current [A]: ', current) | |
print('Power [W]: ', power) # active power (V * I * power factor) | |
print('Energy [Wh]: ', energy) | |
print('Frequency [Hz]: ', frequency) | |
print('Power factor []: ', powerFactor) | |
print('Alarm : ', alarm) | |
# Changing power alarm value to 100 W | |
# master.execute(1, cst.WRITE_SINGLE_REGISTER, 1, output_value=100) | |
try: | |
master.close() | |
if sensor.is_open: | |
sensor.close() | |
except: | |
pass |
@bandaangosta Do you happen to have a TCP-version of this script? I'm now trying to access the data through a serial server running on an ESP-module. I can see from the log (of ESP Easy) that my script connects to the serial server, there's a single blink from a red LED on the PZEM-004t, but no data back :(
edit: Got as far as
import socket, sys
socket.setdefaulttimeout(5)
try:
client = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
except socket.error:
print('Failed to create socket')
sys.exit()
print('Socket Created')
ESP_IP= "*.*.*.*"
ESP_PORT = *
client.connect((ESP_IP,ESP_PORT))
print('Socket Connected to ' + ESP_IP )
try:
print("Send command")
client.send(bytes("\x01\x04\x00\x00\x00\x0A\x70\x0D", 'ascii'))
print("Receive data")
data = client.recv(1024)
print(data)
except socket.error as e:
print(e)
The PZEM-module reacts to this (Rx LED goes on, followed by Tx-LED), but not receiving data back.
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Thank you so much @bandaangosta for your reply. In deed, i was meaning that 0x42 and i was afraid of trying that data to pzem-004t for may i could break it. So, your solution is best. Saving the initial energy value and saving last one and difference is consumption ππ» or calculating energy consumption with Wh formula that contains voltage and current. Again thank you so much for your helpful idea, i will use it ππ»