Skip to content

Instantly share code, notes, and snippets.

@florianl
Created September 21, 2026 17:57
Show Gist options
  • Select an option

  • Save florianl/d47fa6fdfe471b3d03388b348385ef6a to your computer and use it in GitHub Desktop.

Select an option

Save florianl/d47fa6fdfe471b3d03388b348385ef6a to your computer and use it in GitHub Desktop.
driver {
name = aquastreamv2
meter_type = WaterMeter
default_fields = name,id,total_m3,timestamp
detect {
mvt = IMT,f2,07
}
library {
use = total_m3,meter_datetime,target_m3,target_date,flow_temperature_c
}
fields {
field {
name = historic
quantity = PointInTime
info = 'Meter datetime for the historic (storage 8) reading.'
display_unit = datetime
match {
measurement_type = Instantaneous
vif_range = DateTime
storage_nr = 8
}
}
field {
name = historic
quantity = Volume
info = 'Historic (storage 8) volume reading.'
match {
measurement_type = Instantaneous
vif_range = Volume
storage_nr = 8
}
}
field {
name = status
quantity = Text
info = status_and_error_flags
attributes = INCLUDE_TPL_STATUS
match {
measurement_type = Instantaneous
vif_range = ErrorFlags
}
// Bit N assumed to be set for TOPAS ESK 2 "Status Code" N (see product sheet
// TOPAS_ESK_2_1-715-PS-EN-03 chapter 7.5). Codes 98/99 are software/comms level
// and do not fit this 32-bit metrology error mask. Unverified against a real
// telegram with a non-zero status, since none is available yet.
lookup {
name = ERROR_FLAGS
map_type = BitToString
mask_bits = 0xffffffff
default_message = OK
map {
name = TOO_MUCH_COMMUNICATION
info = 'Communication through the optical interface exceeds the threshold (status code 00).'
value = 0x1
test = Set
}
map {
name = CHECKSUM_ERROR
info = 'Data in Flash or RAM is corrupted or was manipulated (status code 01).'
value = 0x2
test = Set
}
map {
name = HARDWARE_TEMPERATURE
info = 'Temperature sensor cable is broken (status code 02).'
value = 0x4
test = Set
}
map {
name = HARDWARE_FLOW
info = 'Hardware error at the flow measuring or ultrasonic sensor (status code 04).'
value = 0x10
test = Set
}
map {
name = LEAKAGE
info = 'Continuous consumption above the leakage threshold for 24 hours (status code 05).'
value = 0x20
test = Set
}
map {
name = BACKFLOW
info = 'Reverse volume above the configurable threshold (status code 06).'
value = 0x40
test = Set
}
map {
name = AIR_IN_PIPE
info = 'Air detected in the pipe (status code 07).'
value = 0x80
test = Set
}
map {
name = LOW_BATTERY
info = 'Calculated battery life is less than 1.5 years (status code 09).'
value = 0x200
test = Set
}
map {
name = UNDERSIZED_METER
info = 'Flow above the undersized meter threshold (status code 11).'
value = 0x800
test = Set
}
map {
name = NO_CONSUMPTION
info = 'Consumption below the no-usage threshold for 30 days (status code 12).'
value = 0x1000
test = Set
}
map {
name = HIGH_MEDIUM_TEMPERATURE
info = 'Medium temperature above the configured threshold (status code 13).'
value = 0x2000
test = Set
}
map {
name = FREEZING_RISK
info = 'Medium temperature below 3°C (status code 14).'
value = 0x4000
test = Set
}
map {
name = FALLBACK_MODE
info = 'Significant deviation of the measurement in the two measuring paths (status code 17).'
value = 0x20000
test = Set
}
map {
name = METROLOGICAL_LOG_ACCESS
info = 'The metrological log has been accessed (status code 18).'
value = 0x40000
test = Set
}
map {
name = MEASUREMENT_INTERFERENCE
info = 'Measurement disturbed by cavitation, air/water mixture or EM interference (status code 22).'
value = 0x400000
test = Set
}
}
}
field {
name = total_backwards
quantity = Volume
match {
measurement_type = Instantaneous
vif_range = Volume
tariff_nr = 1
}
}
field {
name = battery
quantity = Time
display_unit = y
// Divide by 365
force_scale = 0.0027397260273972603
match {
measurement_type = Instantaneous
difvifkey = 02FD74
}
}
}
tests {
test {
args = 'AqWater2 aquastreamv2 88475766 NOKEY'
telegram = 3E44B42566574788F2077A220030052F2F_0C138747020004FD170000000002FD74AE150A5A2901426C3F3C4C130002000084046D3B375C328C041388380100
json = '{"_":"telegram","battery_y":15.205479,"driver":"aquastreamv2","flow_temperature_c":12.9,"historic_datetime":"2026-02-28 23:59","historic_m3":13.888,"id":"88475766","media":"water","name":"AqWater2","status":"OK","target_date":"2025-12-31","target_m3":0.2,"timestamp":"1111-11-11T11:11:11Z","total_m3":24.787}'
fields = 'AqWater2;88475766;24.787;1111-11-11 11:11.11'
comment = 'Telegram from https://github.com/wmbusmeters/wmbusmeters/issues/1793 (Integra TOPAS ESKR 2 Type 173), tagged with 2f2f already-decrypted marker so no key needed.'
}
test {
args = 'AqWater2 aquastreamv2 88475766 NOKEY'
telegram = 3E44B42566574788F2077A6F0030052F2F_0C138150020004FD170000000002FD74AD150A5A1001426C3F3C4C130002000084046D3B375C328C041388380100
json = '{"_":"telegram","battery_y":15.20274,"driver":"aquastreamv2","flow_temperature_c":11,"historic_datetime":"2026-02-28 23:59","historic_m3":13.888,"id":"88475766","media":"water","name":"AqWater2","status":"OK","target_date":"2025-12-31","target_m3":0.2,"timestamp":"1111-11-11T11:11:11Z","total_m3":25.081}'
fields = 'AqWater2;88475766;25.081;1111-11-11 11:11.11'
comment = 'Another decrypted telegram from https://github.com/wmbusmeters/wmbusmeters/issues/1793 comments, same meter at a later reading.'
}
test {
args = 'AqWater2 aquastreamv2 88475766 NOKEY'
telegram = 3E44B42566574788F2077A700030052F2F_0C130051020004FD170000000002FD74AD150A5A0201426C3F3C4C130002000084046D3B375C328C041388380100
json = '{"_":"telegram","battery_y":15.20274,"driver":"aquastreamv2","flow_temperature_c":10.2,"historic_datetime":"2026-02-28 23:59","historic_m3":13.888,"id":"88475766","media":"water","name":"AqWater2","status":"OK","target_date":"2025-12-31","target_m3":0.2,"timestamp":"1111-11-11T11:11:11Z","total_m3":25.1}'
fields = 'AqWater2;88475766;25.1;1111-11-11 11:11.11'
comment = 'Another decrypted telegram from https://github.com/wmbusmeters/wmbusmeters/issues/1793 comments, later reading with a different ACC byte.'
}
}
}
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment