Created
June 10, 2023 18:08
-
-
Save shubham-vunet/d4f64738e8a78178fa64c3827920824a to your computer and use it in GitHub Desktop.
This #Arduino Project can be used to Turn off #Panasonic AC or Any other AC (see IRremoteESP8266) when there is water overflow. Water level can also be #monitored using any pull based #1agent, I am using #telegraf.
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
#include <WiFi.h> | |
#include <ESPmDNS.h> | |
#include <WiFiUdp.h> | |
#include <ArduinoOTA.h> | |
#include <HCSR04.h> | |
#include <Arduino.h> | |
#include <IRremoteESP8266.h> | |
#include <IRsend.h> | |
#include <ir_Panasonic.h> | |
#include <WebServer.h> | |
const char* ssid = "****"; | |
const char* password = "********"; | |
const int ledPin = BUILTIN_LED; | |
const int touch = T3; | |
int trValue = 100; | |
int cnt = 0; | |
const uint16_t kIrLed = T0; // ESP8266 GPIO pin to use. Recommended: 4 (D2). | |
IRPanasonicAc ac(kIrLed); // Set the GPIO used for sending messages. | |
WebServer server(80); | |
void handleRoot() { | |
digitalWrite(ledPin, HIGH); | |
char buffer[40]; | |
sprintf(buffer, "%d", trValue); | |
server.send(200, "text/plain", buffer); | |
digitalWrite(ledPin, LOW); | |
} | |
//no need authentification | |
void handleNotFound() { | |
String message = "File Not Found"; | |
server.send(404, "text/plain", message); | |
} | |
void setup() { | |
pinMode(ledPin, OUTPUT); | |
Serial.begin(115200); | |
Serial.println("Booting"); | |
WiFi.mode(WIFI_STA); | |
WiFi.begin(ssid, password); | |
while (WiFi.waitForConnectResult() != WL_CONNECTED) { | |
Serial.println("Connection Failed! Rebooting..."); | |
delay(5000); | |
ESP.restart(); | |
} | |
// Port defaults to 3232 | |
ArduinoOTA.setPort(3232); | |
// Hostname defaults to esp3232-[MAC] | |
ArduinoOTA.setHostname("AC-Level-monitor"); | |
// No authentication by default | |
ArduinoOTA.setPassword("****"); | |
// Password can be set with it's md5 value as well | |
// MD5(admin) = 21232f297a57a5a743894a0e4a801fc3 | |
// ArduinoOTA.setPasswordHash("21232f297a57a5a743894a0e4a801fc3"); | |
ArduinoOTA | |
.onStart([]() { | |
String type; | |
if (ArduinoOTA.getCommand() == U_FLASH) | |
type = "sketch"; | |
else // U_SPIFFS | |
type = "filesystem"; | |
// NOTE: if updating SPIFFS this would be the place to unmount SPIFFS using SPIFFS.end() | |
Serial.println("Start updating " + type); | |
}) | |
.onEnd([]() { | |
Serial.println("\nEnd"); | |
}) | |
.onProgress([](unsigned int progress, unsigned int total) { | |
Serial.printf("Progress: %u%%\r", (progress / (total / 100))); | |
}) | |
.onError([](ota_error_t error) { | |
Serial.printf("Error[%u]: ", error); | |
if (error == OTA_AUTH_ERROR) Serial.println("Auth Failed"); | |
else if (error == OTA_BEGIN_ERROR) Serial.println("Begin Failed"); | |
else if (error == OTA_CONNECT_ERROR) Serial.println("Connect Failed"); | |
else if (error == OTA_RECEIVE_ERROR) Serial.println("Receive Failed"); | |
else if (error == OTA_END_ERROR) Serial.println("End Failed"); | |
}); | |
ArduinoOTA.begin(); | |
Serial.println("Ready"); | |
Serial.print("IP address: "); | |
Serial.println(WiFi.localIP()); | |
ac.begin(); | |
ac.setModel(kPanasonicCkp); | |
server.on("/", handleRoot); | |
server.onNotFound(handleNotFound); | |
server.begin(); | |
} | |
void loop() { | |
ArduinoOTA.handle(); | |
server.handleClient(); | |
trValue = touchRead(touch); | |
Serial.println(trValue); | |
if (trValue < 20 && cnt > 4) { | |
#if SEND_PANASONIC_AC | |
ac.off(); | |
ac.send(); | |
#endif | |
if(cnt > 6){ | |
cnt = -100; | |
} | |
} | |
digitalWrite(ledPin, HIGH); | |
sleep(1); | |
digitalWrite(ledPin, LOW); | |
if (trValue < 20) { | |
sleep(1); | |
cnt = cnt+1; | |
} else { | |
sleep(5); | |
cnt = 0; | |
} | |
} |
Sign up for free