#!/usr/bin/python3 | |
## which serial port the MPP Solar inverter is connected to | |
serial_port = '/dev/ttyS0' | |
### | |
import serial ## provided by 'pyserial' from pip | |
import crc16 ## provided by 'crc16' from pip | |
import sys ## inbuilt library | |
def send(ser, command) : | |
## convert the command to bytes | |
command_bytes = command.encode('utf-8') | |
## calculate the CRC16 checksum of the command | |
crc = crc16.crc16xmodem(command_bytes).to_bytes(2, 'big') | |
## add the CRC and a carrige-return to the command | |
command_send = command_bytes + crc + b'\r' | |
## send the command | |
print('Sending: ' + str(command_send)) | |
ser.write(command_send) | |
## flush the serial buffer to make sure the command is sent | |
ser.flush() | |
## open the serial port as 2400-8-N-1 | |
serial_connection = serial.Serial(serial_port, 2400, timeout = 1) | |
## send the command passed as the first command-line argument | |
send(serial_connection, sys.argv[1]) | |
## get the response | |
response = serial_connection.readline()[:-1] | |
## get the response checksum | |
checksum_received = response[-2:] | |
## get the response data and convert it to a string | |
data = response[1:-2].decode('utf-8') | |
## calculate the response checksum | |
checksum_actual = crc16.crc16xmodem(response[:-2]).to_bytes(2, 'big') | |
## print the response if the checksum is ok | |
if checksum_received == checksum_actual: | |
print('Data: ' + str(data)) | |
else: | |
print('ERROR: Checksum mismatch!') |