Must inverter ESPHome configuration for ESP32. More info and the latest version of the config are now in the repo: https://github.com/vladyspavlov/esphome-must-inverter
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
# More info and the latest version of the config are now in the repo: https://github.com/vladyspavlov/esphome-must-inverter | |
substitutions: | |
inverter_id: inverter | |
updates: 5s | |
api_key: xxx | |
ota_password: xxx | |
esphome: | |
name: inverter-monitor | |
comment: "Inverter monitor" | |
esp32: | |
board: esp32dev | |
framework: | |
type: esp-idf | |
wifi: | |
ssid: !secret wifi_ssid | |
password: !secret wifi_password | |
captive_portal: | |
logger: | |
level: DEBUG | |
api: | |
encryption: | |
key: ${api_key} | |
ota: | |
password: ${ota_password} | |
uart: | |
- id: uart_inverter | |
baud_rate: 19200 | |
tx_pin: GPIO19 | |
rx_pin: GPIO18 | |
stop_bits: 1 | |
parity: NONE | |
data_bits: 8 | |
debug: | |
direction: BOTH | |
dummy_receiver: false | |
modbus: | |
- id: modbus_inverter | |
uart_id: uart_inverter | |
send_wait_time: 200ms | |
modbus_controller: | |
- id: must_inverter | |
address: 0x04 | |
modbus_id: modbus_inverter | |
command_throttle: 200ms | |
setup_priority: -10 | |
update_interval: ${updates} | |
sensor: | |
# charger sensors | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 15201 | |
name: "PV Charger Workstate" | |
register_type: holding | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 15202 | |
name: "PV Charger MPPT state" | |
register_type: holding | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 15203 | |
name: "PV Charger Charging state" | |
register_type: holding | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 15205 | |
name: "PV Charger Voltage" | |
register_type: holding | |
unit_of_measurement: "V" | |
accuracy_decimals: 1 | |
icon: mdi:sine-wave | |
filters: | |
multiply: 0.1 | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 15206 | |
name: "PV Charger Battery voltage" | |
register_type: holding | |
unit_of_measurement: "V" | |
accuracy_decimals: 1 | |
icon: mdi:sine-wave | |
filters: | |
multiply: 0.1 | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 15207 | |
name: "PV Charger Current" | |
register_type: holding | |
unit_of_measurement: "A" | |
accuracy_decimals: 1 | |
icon: mdi:current-dc | |
filters: | |
multiply: 0.1 | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 15208 | |
register_type: holding | |
name: "PV Charger power" | |
unit_of_measurement: "W" | |
accuracy_decimals: 1 | |
icon: mdi:flash | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 15209 | |
register_type: holding | |
name: "PV Charger Radiator temp" | |
unit_of_measurement: "°C" | |
accuracy_decimals: 1 | |
icon: mdi:temperature-celsius | |
# - platform: modbus_controller | |
# modbus_controller_id: must_inverter | |
# address: 15210 | |
# register_type: holding | |
# name: "PV Charger External temp" | |
# unit_of_measurement: "°C" | |
# accuracy_decimals: 1 | |
# icon: mdi:temperature-celsius | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 15212 | |
register_type: holding | |
name: "PV Relay" | |
icon: mdi:electric-switch | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 15217 | |
register_type: holding | |
id: charger_total_mwh | |
internal: true | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 15218 | |
register_type: holding | |
id: charger_total_kwh | |
internal: true | |
filters: | |
multiply: 0.1 | |
- platform: template | |
name: "PV Charger Accumulated charger power" | |
unit_of_measurement: kWh | |
lambda: !lambda 'return (id(charger_total_mwh).state * 1000.0 + id(charger_total_kwh).state );' | |
accuracy_decimals: 1 | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 15219 | |
register_type: holding | |
name: "PV Charger Accumulated day" | |
unit_of_measurement: "W" | |
accuracy_decimals: 1 | |
icon: mdi:flash | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 15220 | |
register_type: holding | |
name: "PV Charger Accumulated hour" | |
unit_of_measurement: "W" | |
accuracy_decimals: 1 | |
icon: mdi:flash | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 15221 | |
register_type: holding | |
name: "PV Charger Accumulated minute" | |
unit_of_measurement: "W" | |
accuracy_decimals: 1 | |
icon: mdi:flash | |
# inverter sensors | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25201 | |
register_type: holding | |
name: "Inverter Work state" | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25205 | |
name: "Inverter Battery Voltage" | |
register_type: holding | |
unit_of_measurement: "V" | |
accuracy_decimals: 1 | |
icon: mdi:sine-wave | |
filters: | |
multiply: 0.1 | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25206 | |
name: "Inverter Voltage" | |
register_type: holding | |
unit_of_measurement: "V" | |
accuracy_decimals: 1 | |
icon: mdi:sine-wave | |
filters: | |
multiply: 0.1 | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25207 | |
name: "Inverter Grid voltage" | |
register_type: holding | |
unit_of_measurement: "V" | |
accuracy_decimals: 1 | |
icon: mdi:sine-wave | |
filters: | |
multiply: 0.1 | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25207 | |
name: "Inverter Grid voltage" | |
register_type: holding | |
unit_of_measurement: "V" | |
accuracy_decimals: 1 | |
icon: mdi:sine-wave | |
filters: | |
multiply: 0.1 | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25208 | |
name: "Inverter BUS Voltage" | |
register_type: holding | |
unit_of_measurement: "V" | |
accuracy_decimals: 1 | |
icon: mdi:sine-wave | |
filters: | |
multiply: 0.1 | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25209 | |
name: "Inverter Control current" | |
register_type: holding | |
unit_of_measurement: "A" | |
accuracy_decimals: 1 | |
icon: mdi:current-dc | |
filters: | |
multiply: 0.1 | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25210 | |
name: "Inverter Current" | |
register_type: holding | |
unit_of_measurement: "A" | |
accuracy_decimals: 1 | |
icon: mdi:current-dc | |
filters: | |
multiply: 0.1 | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25211 | |
name: "Inverter Grid current" | |
register_type: holding | |
unit_of_measurement: "A" | |
accuracy_decimals: 1 | |
icon: mdi:current-ac | |
filters: | |
multiply: 0.1 | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25212 | |
name: "Inverter Load current" | |
register_type: holding | |
unit_of_measurement: "A" | |
accuracy_decimals: 1 | |
icon: mdi:current-ac | |
filters: | |
multiply: 0.1 | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25213 | |
name: "Inverter Power" | |
register_type: holding | |
unit_of_measurement: "W" | |
accuracy_decimals: 1 | |
icon: mdi:flash | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25214 | |
name: "Inverter Grid power" | |
register_type: holding | |
unit_of_measurement: "W" | |
accuracy_decimals: 1 | |
value_type: S_WORD | |
icon: mdi:flash | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25215 | |
name: "Inverter Load power" | |
register_type: holding | |
unit_of_measurement: "W" | |
accuracy_decimals: 1 | |
icon: mdi:flash | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25216 | |
name: "Inverter System load" | |
register_type: holding | |
unit_of_measurement: "%" | |
accuracy_decimals: 1 | |
icon: mdi:flash | |
# MOST INFO | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25233 | |
register_type: holding | |
name: "Inverter AC radiator temp" | |
accuracy_decimals: 1 | |
unit_of_measurement: "°C" | |
icon: mdi:temperature-celsius | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25234 | |
register_type: holding | |
name: "Inverter Transformer temp" | |
unit_of_measurement: "°C" | |
accuracy_decimals: 1 | |
icon: mdi:temperature-celsius | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25235 | |
register_type: holding | |
name: "Inverter DC Radiator temp" | |
unit_of_measurement: "°C" | |
accuracy_decimals: 1 | |
icon: mdi:temperature-celsius | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25237 | |
register_type: holding | |
name: "Inverter Relay state" | |
icon: mdi:electric-switch | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25238 | |
register_type: holding | |
name: "Inverter Relay state Grid" | |
icon: mdi:electric-switch | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25239 | |
register_type: holding | |
name: "Inverter Relay state Load" | |
icon: mdi:electric-switch | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25240 | |
register_type: holding | |
name: "Inverter Relay state NLine" | |
icon: mdi:electric-switch | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25241 | |
register_type: holding | |
name: "Inverter Relay state DC" | |
icon: mdi:electric-switch | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25242 | |
register_type: holding | |
name: "Inverter Relay state Earth" | |
icon: mdi:electric-switch | |
# Inverter Accumulated discharge power | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25247 | |
register_type: holding | |
id: discharger_total_mwh | |
internal: true | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25248 | |
register_type: holding | |
id: discharger_total_kwh | |
internal: true | |
filters: | |
multiply: 0.1 | |
- platform: template | |
name: "Accumulated discharger power" | |
unit_of_measurement: kWh | |
accuracy_decimals: 1 | |
lambda: !lambda 'return (id(discharger_total_mwh).state * 1000.0 + id(discharger_total_kwh).state);' | |
# Inverter Accumulated buy power | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25249 | |
register_type: holding | |
id: buy_mwh | |
internal: true | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25250 | |
register_type: holding | |
id: buy_kwh | |
internal: true | |
filters: | |
multiply: 0.1 | |
- platform: template | |
name: "Accumulated buy power" | |
unit_of_measurement: kWh | |
lambda: |- | |
return (id(buy_mwh).state * 1000.0 + id(buy_kwh).state); | |
accuracy_decimals: 1 | |
# Inverter Accumulated sell power | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25251 | |
register_type: holding | |
id: sell_mwh | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25252 | |
register_type: holding | |
id: sell_kwh | |
filters: | |
multiply: 0.1 | |
- platform: template | |
name: "Accumulated sell power" | |
unit_of_measurement: kWh | |
accuracy_decimals: 1 | |
lambda: !lambda return (id(sell_mwh).state * 1000.0 + id(sell_kwh).state); | |
# Inverter Accumulated load power | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25253 | |
register_type: holding | |
id: load_mwh | |
internal: True | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25254 | |
register_type: holding | |
id: load_kwh | |
internal: True | |
filters: | |
multiply: 0.1 | |
- platform: template | |
name: "Accumulated load power" | |
unit_of_measurement: kWh | |
accuracy_decimals: 1 | |
lambda: !lambda return (id(load_mwh).state * 1000.0 + id(load_kwh).state); | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25273 | |
register_type: holding | |
value_type: S_WORD | |
name: "Inverter Battery power" | |
unit_of_measurement: "W" | |
accuracy_decimals: 1 | |
icon: mdi:flash | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25274 | |
register_type: holding | |
value_type: S_WORD | |
name: "Inverter Battery current" | |
unit_of_measurement: "A" | |
accuracy_decimals: 1 | |
icon: mdi:current-dc | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25275 | |
register_type: holding | |
value_type: S_WORD | |
name: "Inverter Battery grade" | |
unit_of_measurement: "V" | |
icon: mdi:alpha-V | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 25277 | |
register_type: holding | |
name: "Inverter Rated power" | |
unit_of_measurement: "W" | |
accuracy_decimals: 1 | |
icon: mdi:flash | |
select: | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
id: energy_use_mode | |
name: "Inverter Energy use mode (parameter 00)" | |
address: 20109 | |
optionsmap: | |
"SBU (Solar/battery/utility)": 1 | |
"SUB (Solar/utility/battery)": 2 | |
"UTI (Utility only)": 3 | |
"SOL (Solar only)": 4 | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
id: charger_source_priority | |
name: "Inverter Charger source priority (parameter 10)" | |
address: 20143 | |
optionsmap: | |
"CSO (Solar first)": 0 | |
"SNU (Solar and utility)": 2 | |
"OSO (Solar only)": 3 | |
- platform: modbus_controller | |
modbus_controller_id: must_inverter | |
address: 20111 | |
id: inverter_ac_input_voltage_range | |
name: "Inverter AC input voltage range (02)" | |
optionsmap: | |
"VDE (184-253VAC)": 0 | |
"UPS (170-280VAC)": 1 | |
"APL (90-280VAC)": 2 | |
"GEN (Generator)": 3 | |
number: | |
- platform: modbus_controller | |
id: batt_float_voltage | |
name: "PV Charger Float voltage" | |
unit_of_measurement: "V" | |
address: 10103 | |
value_type: U_WORD | |
multiply: 10 | |
- platform: modbus_controller | |
id: batt_absorb_voltage | |
name: "PV Charger Absorb voltage" | |
unit_of_measurement: "V" | |
address: 10104 | |
value_type: U_WORD | |
multiply: 10 | |
- platform: modbus_controller | |
id: batt_stop_dischg | |
name: "Inverter Battery stop discharging voltage" | |
unit_of_measurement: "V" | |
address: 20118 | |
value_type: U_WORD | |
lambda: "return x * 0.1; " | |
write_lambda: |- | |
return x * 10 ; | |
- platform: modbus_controller | |
id: batt_stop_chg | |
name: "Inverter Battery stop charging voltage" | |
unit_of_measurement: "V" | |
address: 20119 | |
value_type: U_WORD | |
multiply: 10 | |
- platform: modbus_controller | |
id: batt_low_voltage | |
name: "Inverter Battery low voltage" | |
unit_of_measurement: "V" | |
address: 20127 | |
value_type: U_WORD | |
multiply: 10 | |
- platform: modbus_controller | |
id: batt_high_voltage | |
name: "Inverter Battery high voltage" | |
unit_of_measurement: "V" | |
address: 20128 | |
value_type: U_WORD | |
multiply: 10 | |
- platform: modbus_controller | |
id: solar_charger_current | |
name: "Inverter Charger current" | |
unit_of_measurement: "A" | |
address: 20132 | |
value_type: U_WORD | |
multiply: 10 |
общался по тел указаному выше . Китайцы крутят, на вопрос толком не отвечают. А менять регистры вслепую страшно.
pv18 есть таблица .как добавить ?
pv18 есть таблица .как добавить ?
https://github.com/vladyspavlov/esphome-must-inverter
Тут може вже є, те що ви шукали.
Якщо у вас щось новеньке, то додайте пул реквест, будь ласка
добавить нечего , все есть.
может кому надо
text_sensor:
- platform: modbus_controller
modbus_controller_id: d
id: Charger_workstate_d
name: "Charger workstate"
address: 15201
register_type: holding
raw_encode: HEXBYTES
lambda: |-
uint16_t value = modbus_controller::word_from_hex_str(x, 0);
switch (value) {
case 0: return std::string("Initialization Mode");
case 1: return std::string("Selftest Mode");
case 2: return std::string("Work Mode");
case 3: return std::string("Stop Mode");
default: return std::string("Unknown");
}
return x;