Save wildekek/4e19fb049eb7cea3a35fe801e3ed8f57 to your computer and use it in GitHub Desktop.
# Creates Home Assistant Power and Energy sensors for APSystems ECU-C | |
# Copy this file to /homeassistant/packages/ecu.yaml | |
# Add the following lines to the /homeassistant/configuration.yaml: | |
# homeassistant: | |
# packages: | |
# system: !include packages/ecu.yaml | |
# Update the IP (192.168.0.6) to the address your ECU runs at | |
# Update the ECUID (215000015509) to your ECUID. You can find this on the main webpage of the ECU | |
rest: | |
# Fetch power data | |
# This data is generated by measuring the CT clamps. | |
- resource: "http://192.168.0.6/index.php/hidden/set_get_app_info_json" | |
method: POST | |
scan_interval: 300 | |
payload: '{"Command_Id": "53","APS": "ASK","Command": "1","Version": "1.1","ECUID": "215000015509"}' | |
sensor: | |
- name: Solar Power Produced L1 | |
unique_id: solar_power_produced_l1 | |
unit_of_measurement: kW | |
state_class: measurement | |
device_class: power | |
value_template: '{{ value_json["meter_data"]["power1"][-1]["powerA"] / 1000}}' | |
- name: Solar Power Produced L2 | |
unique_id: solar_power_produced_l2 | |
unit_of_measurement: kW | |
state_class: measurement | |
device_class: power | |
value_template: '{{ value_json["meter_data"]["power1"][-1]["powerB"] / 1000 }}' | |
- name: Solar Power Produced L3 | |
unique_id: solar_power_produced_l3 | |
unit_of_measurement: kW | |
state_class: measurement | |
device_class: power | |
value_template: '{{ value_json["meter_data"]["power1"][-1]["powerC"] / 1000 }}' | |
- name: Grid Power Produced L1 | |
unique_id: grid_power_produced_l1 | |
unit_of_measurement: kW | |
state_class: measurement | |
device_class: power | |
value_template: >- | |
{% set power = value_json["meter_data"]["power2"][-1]["powerA"] / 1000 %} | |
{% if power < 0 %} | |
{{ power * -1 }} | |
{% else %} | |
0 | |
{% endif %} | |
- name: Grid Power Produced L2 | |
unique_id: grid_power_produced_l2 | |
unit_of_measurement: kW | |
state_class: measurement | |
device_class: power | |
value_template: >- | |
{% set power = value_json["meter_data"]["power2"][-1]["powerB"] / 1000 %} | |
{% if power < 0 %} | |
{{ power * -1 }} | |
{% else %} | |
0 | |
{% endif %} | |
- name: Grid Power Produced L3 | |
unique_id: grid_power_produced_l3 | |
unit_of_measurement: kW | |
state_class: measurement | |
device_class: power | |
value_template: >- | |
{% set power = value_json["meter_data"]["power2"][-1]["powerC"] / 1000 %} | |
{% if power < 0 %} | |
{{ power * -1 }} | |
{% else %} | |
0 | |
{% endif %} | |
- name: Grid Power Consumed L1 | |
unique_id: grid_power_consumed_l1 | |
unit_of_measurement: kW | |
state_class: measurement | |
device_class: power | |
value_template: >- | |
{% set power = value_json["meter_data"]["power2"][-1]["powerA"] / 1000 %} | |
{% if power > 0 %} | |
{{ power }} | |
{% else %} | |
0 | |
{% endif %} | |
- name: Grid Power Consumed L2 | |
unique_id: grid_power_consumed_l2 | |
unit_of_measurement: kW | |
state_class: measurement | |
device_class: power | |
value_template: >- | |
{% set power = value_json["meter_data"]["power2"][-1]["powerB"] / 1000 %} | |
{% if power > 0 %} | |
{{ power }} | |
{% else %} | |
0 | |
{% endif %} | |
- name: Grid Power Consumed L3 | |
unique_id: grid_power_consumed_l3 | |
unit_of_measurement: kW | |
state_class: measurement | |
device_class: power | |
value_template: >- | |
{% set power = value_json["meter_data"]["power2"][-1]["powerC"] / 1000 %} | |
{% if power > 0 %} | |
{{ power }} | |
{% else %} | |
0 | |
{% endif %} | |
- name: Domestic Power Consumed L1 | |
unique_id: domestic_power_consumed_l1 | |
unit_of_measurement: kW | |
state_class: measurement | |
device_class: power | |
value_template: '{{ (value_json["meter_data"]["power1"][-1]["powerA"] + value_json["meter_data"]["power2"][-1]["powerA"]) / 1000 }}' | |
- name: Domestic Power Consumed L2 | |
unique_id: domestic_power_consumed_l2 | |
unit_of_measurement: kW | |
state_class: measurement | |
device_class: power | |
value_template: '{{ (value_json["meter_data"]["power1"][-1]["powerB"] + value_json["meter_data"]["power2"][-1]["powerB"]) / 1000 }}' | |
- name: Domestic Power Consumed L3 | |
unique_id: domestic_power_consumed_l3 | |
unit_of_measurement: kW | |
state_class: measurement | |
device_class: power | |
value_template: '{{ (value_json["meter_data"]["power1"][-1]["powerC"] + value_json["meter_data"]["power2"][-1]["powerC"]) / 1000 }}' | |
# Fetch energy data | |
# This data is generated by measuring the CT clamps. | |
scrape: | |
- resource: http://192.168.0.6/index.php/display/historical_data/meter_lifetime_energy/ | |
scan_interval: 300 | |
sensor: | |
- name: Solar Energy | |
unique_id: solar_energy | |
unit_of_measurement: kWh | |
device_class: energy | |
state_class: total | |
select: "div.table-responsive > table > tbody > tr:nth-of-type(1) > td:nth-of-type(3)" | |
value_template: '{{ value| float | round(3) }}' | |
- name: Grid Energy | |
unique_id: grid_energy | |
unit_of_measurement: kWh | |
device_class: energy | |
state_class: total | |
select: "div.table-responsive > table > tbody > tr:nth-of-type(2) > td:nth-of-type(3)" | |
value_template: '{{ value| float | round(3) }}' | |
template: | |
sensor: | |
# We need the inverted Grid Energy to feed the Grid Production meter | |
- name: "Grid Energy Inverted" | |
unique_id: grid_energy_inverted | |
state_class: total | |
device_class: energy | |
unit_of_measurement: "kWh" | |
state: "{{ states('sensor.grid_energy') | float * -1 }}" | |
utility_meter: | |
solar_energy_produced: | |
name: "Solar Energy Produced" | |
unique_id: solar_energy_produced | |
source: sensor.solar_energy | |
delta_values: false | |
net_consumption: false | |
periodically_resetting: false | |
grid_energy_consumed: | |
name: "Grid Energy Consumed" | |
unique_id: grid_energy_consumed | |
source: sensor.grid_energy | |
delta_values: false | |
net_consumption: false | |
periodically_resetting: false | |
grid_energy_produced: | |
name: "Grid Energy Produced" | |
unique_id: grid_energy_produced | |
source: sensor.grid_energy_inverted | |
delta_values: false | |
net_consumption: false | |
periodically_resetting: false | |
sensor: | |
# Calculate total power values | |
- platform: min_max | |
name: Solar Power Produced | |
unique_id: solar_power_produced | |
round_digits: 3 | |
type: sum | |
entity_ids: | |
- sensor.solar_power_produced_l1 | |
- sensor.solar_power_produced_l2 | |
- sensor.solar_power_produced_l3 | |
- platform: min_max | |
name: Grid Power Produced | |
unique_id: grid_power_produced | |
round_digits: 3 | |
type: sum | |
entity_ids: | |
- sensor.grid_power_produced_l1 | |
- sensor.grid_power_produced_l2 | |
- sensor.grid_power_produced_l3 | |
- platform: min_max | |
name: Grid Power Consumed | |
unique_id: grid_power_consumed | |
round_digits: 3 | |
type: sum | |
entity_ids: | |
- sensor.grid_power_consumed_l1 | |
- sensor.grid_power_consumed_l2 | |
- sensor.grid_power_consumed_l3 | |
- platform: min_max | |
name: Domestic Power Consumed | |
unique_id: domestic_power_consumed | |
round_digits: 3 | |
type: sum | |
entity_ids: | |
- sensor.domestic_power_consumed_l1 | |
- sensor.domestic_power_consumed_l2 | |
- sensor.domestic_power_consumed_l3 |
So.... it works?
Keep in mind that:
- The scrape interval is 300s, so you'll only have data available after 5 mins. (the ECU only updates this data every 5 mins: ¯_(ツ)_/¯ .
- These sensors will only be available after a restart of HA.
You're not giving me a lot to go on there buddy. That said, I don't think data is 'gone' but was just acquired at a later point in time. Probably Home Assistant was unable to reach the ECU for some reason. I would not worry about it too much tbh.




Hello,
I have followed all the steps provided, however, I still see zero production despite another consumption tracking module indicating overproduction. I specifically need the status "sensor.solar_energy_produced". The version of the add-on "APSystems ECU-R" I am using is v1.4.1.
Could you please assist me with this?
Thank you in advance.
Edit : After uninstall / reinstall its work now
Thank you for this code @wildekek . It works perfectly :-)
Hey @wildekek, I would like to suggest one additional feature that will add the "Imported/Exported" sensor to Home Assistant replicating the values you get in the APSystems app. That would be the grey line in the screenshot below:
We can get these values from this URL: 'http:///index.php/meter/old_meter_power_graph'
To create this new sensor would only require adding the code below to the existing ecu.yaml
# Update the IP (192.168.0.6) to the address your ECU runs at
- platform: rest
name: "Import Export Power" # Grid Import is (+) / Export is (-)
unique_id: import_export_power
device_class: power
state_class: measurement
unit_of_measurement: W
resource: http://192.168.0.6/index.php/meter/old_meter_power_graph
scan_interval: 300
value_template: >
{% if value_json is defined %}
{{ value_json.power2[-1].powerA }}
{% else %}
{{ "None" }}
{% endif %}
Please, let me know what you think. And congratulations again for the great work.
Hello, as there is a clamp at the counter, which entity corresponds to consumption or instant injection? I need to recover this value. Thanks for the work
Bonjour,
Avant de commencer l'intégration je voudrais savoir si vous avez eu des coupures pour être obliger de redémarrer l'ECU_C ?
Merci
OK, peut-être un problème avec mon configuration.yaml...
Est-ce correct ? `#renvoi vers sensors sensor: !include sensors.yaml automation: !include automations.yaml script: !include scripts.yaml scene: !include scenes.yaml
#renvoi vers les paquets (ECU-C) homeassistant: packages: system: !include packages/ecu.yaml`
Je peux voir des capteurs dans les outils de développement mais je ne peux pas les sélectionner sur mon tableau de bord énergétique.
OK, peut-être un problème avec mon configuration.yaml...
Est-ce correct ? `#renvoi vers sensors sensor: !include sensors.yaml automation: !include automations.yaml script: !include scripts.yaml scene: !include scenes.yaml
#renvoi vers les paquets (ECU-C) homeassistant: packages: system: !include packages/ecu.yaml`
Je peux voir des capteurs dans les outils de développement mais je ne peux pas les sélectionner sur mon tableau de bord énergétique.
ca ne marche pas
pouvez vous refaire le yaml en entier
merci de votre retour
ca ne marche pas
pouvez vous refaire le yaml en entier
merci de votre retour
Hi, since yesterday, i can't get data anymore...Do you know if anything has changed ??
Ok, it seems to be OK... ???